 "status_at_freeze":"prepared-not-run",
 "reason":"Main bridge test completed and failed fixed direction criteria. Diagnose whether matched direct activity at HS/H2 can elicit both anatomically labelled DNp15 channels; do not change the bridge's gain, signs or success criterion.",
 "seeds":[20261101,20261102,20261103],
 "conditions":["quiet","A","B"],
 "duration_ms":1000,"dt_ms":0.1,"stimulus_start_ms":200,"stimulus_end_ms":700,"rate_hz_per_template_cell":150,
 "template":["HSN","HSE","HSS","H2"],
 "A_targets":["HSN_left","HSE_left","HSS_left","H2_right"],
 "B_targets":["HSN_right","HSE_right","HSS_right","H2_left"],
 "input_matching":"The same four-channel candidate events per seed are mapped to mirror targets for A and B. Quiet uses the same candidate events with gate0. All8 potential HS/H2 inputs use refractory0ms per the original author's stimulation convention; no descending output is directly stimulated.",
 "criterion":"For every new seed, DNp15 left>right under A, right>left under B; quiet outputs0. Preserve the same anatomical readout signs. Report DNa02 secondarily with no output selection. No gain fitting.",
 "interpretation":"A diagnostic only. A pass would show that this direct upstream drive can access both channels, without establishing the unique reason the visual bridge failed. A failure would not distinguish anatomical asymmetry, absent electrical connections, model dynamics or annotation assumptions. No visual perception, autonomous behavior, plasticity or body control is tested here."
}